Auditoría energética en la comunicad de regantes "el Saso" de Aibar con apoyo de simuladores hidráulicos

dc.contributor.advisorTFECampo-Bescós, Miguel
dc.contributor.affiliationEscuela Técnica Superior de Ingenieros Agrónomoses_ES
dc.contributor.affiliationNekazaritza Ingeniarien Goi Mailako Eskola Teknikoaeu
dc.contributor.authorMartínez Esandi, Marta
dc.coverage.spatialeast=-1.3601865000000543; north=42.5931438; name=31460 Aibar, Navarra, España
dc.date.accessioned2015-11-23T10:42:16Z
dc.date.available2015-11-23T10:42:16Z
dc.date.issued2015
dc.date.updated2015-11-03T08:00:39Z
dc.description.abstractEn este Trabajo Fin de Grado se realiza una auditoría energética en la comunidad de regantes “El Saso” de Aibar (Navarra), complementada con un análisis del comportamiento hidráulico de la red de distribución. Para el análisis se utilizan dos simuladores hidráulicos: Gestar y Epanet, de manera que permite, a su vez, comparar las posibilidades de cálculo de uno y otro simulador. En primer lugar, se aborda el análisis energético teniendo en cuenta el diseño y funcionamiento de la instalación, la eficiencia energética general (EG) y de los equipos de bombeo (EB) y, la adecuación de la tarifa eléctrica en cuanto a las potencias contratadas y discriminación horaria del consumo energético. Se estudia, además, la presión de consigna del bombeo con el apoyo de Gestar para optimizar, en cada punto de la red, las presiones servidas. El trabajo se completa con una comparativa entre Gestar y Epanet, programas informáticos específicos para el análisis y gestión de redes presurizadas, con la particularidad de que se aportan datos reales obtenidos sobre el terreno. Como conclusión, con los resultados de este estudio se comprueba, por una parte, la adecuada gestión realizada por la comunidad de regantes en lo referente al consumo energético y, las posibilidades de ahorro que ofrece la calibración de la presión de consigna programada en la estación de bombeo, y por otra parte, las diferencias de cálculo obtenidas entre los simuladores y los datos de campo son consideradas aceptables.es_ES
dc.description.abstractIn this paper an energy audit is conducted in the irrigation community "El Saso" of Aibar (Navarra) and is complemented by an analysis of the hydraulic behavior of the distribution network. This analysis is performed, simultaneously, with two hydraulic simulators: Gestar and Epanet, so that serves, in addition, to compare the chances of calculating with both simulators. Firstly, the energy analysis is addressed considering the installation design and operation, the overall energy efficiency (OE) and pumping equipment (PE), and the adequacy of the electricity tariff as to the contracted powers and discrimination hourly energy consumption. Set point pressure pumping supported to adjust the maximum total pressure at every each point of the network is also studied. The work is complemented by a comparison between Gestar and Epanet, specific software to the analysis and management of pressurized networks with the peculiarity that actual measured field data are provided. In conclusion, the results obtained in this study show, in one hand, right management by the irrigation community in regard to energy consumption and saving possibilities offered by the calibration of the pressure set point programmed station pumping and, on the other hand, computed differences observed between the simulator and field data are acceptable.en
dc.description.degreeGraduado o Graduada en Ingeniería Agroalimentaria y del Medio Rural por la Universidad Pública de Navarraes_ES
dc.description.degreeNekazaritzako Elikagaien eta Landa Ingurunearen Ingeniaritzan graduatua Nafarroako Unibertsitate Publikoaneu
dc.format.mimetypeapplication/pdfen
dc.identifier.urihttps://academica-e.unavarra.es/handle/2454/19401
dc.language.isospaen
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.subjectEficiencia energéticaes_ES
dc.subjectAuditoría energéticaes_ES
dc.subjectComunidad de reganteses_ES
dc.subjectSimulador hidráulicoes_ES
dc.subjectAnálisis hidráulicoes_ES
dc.subjectEnergy efficiencyen
dc.subjectEnergy auditen
dc.subjectIrrigation communityen
dc.subjectHydraulic simulatoren
dc.subjectHydraulic analysisen
dc.subject.geoIngeniería agroalimentariaes_ES
dc.titleAuditoría energética en la comunicad de regantes "el Saso" de Aibar con apoyo de simuladores hidráulicoses_ES
dc.typeinfo:eu-repo/semantics/bachelorThesis
dspace.entity.typePublication
relation.isAdvisorTFEOfPublicatione9ca0d9f-24bc-4ce1-871f-81ce4e86b5bd
relation.isAdvisorTFEOfPublication.latestForDiscoverye9ca0d9f-24bc-4ce1-871f-81ce4e86b5bd

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
TFG_MartaMartinez.pdf
Size:
30.9 MB
Format:
Adobe Portable Document Format
Description:
Embargado hasta: 01-06-2020
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.78 KB
Format:
Item-specific license agreed to upon submission
Description: