Low-cost optical fiber multimode interference biosensor based on a glucose sensitive Glucose-Oxidase enzyme thin-film

Date

2024-12-04

Authors

Rodríguez Rodríguez, Wenceslao Eduardo
Rodríguez Rodríguez, Adolfo Josué
Juárez-Saldivar, Alfredo

Director

Publisher

Elsevier
Acceso abierto / Sarbide irekia
Artículo / Artikulua
Versión publicada / Argitaratu den bertsioa

Project identifier

Impacto
OpenAlexGoogle Scholar
No disponible en Scopus

Abstract

In this research we report a contribution for the development of low-cost fiber optical biosensors fabricated by the Single Mode-Multi Mode-Single Mode configuration applied for the glucose monitoring considering clinical concentrations ranges in aqueous analytes. Designed devices are evaluated using health standard detection ranges, such as healthy, pre-diabetic, and diabetic stages operating at the visible spectral region. The sensing regions has been prepared by the etching technique in order to improve the interaction between the evanescent wave with the surrounding medium followed by functionalization of enzyme oxidase glucose via the electrostatic self-assembly using by Poly(allylamine hydrochloride) as an immobilizer matrix. The increase of bilayers number over the sensor surface permits us to demonstrate the enhancement of sensitivity and limit of detection. Experimental results permitted the glucose characterization in the range from 0.3 to 2.4 mg mL-1 obtaining a response time of 9 s and a sensitivity of 1.8 nm/(mg mL-1) allowing to detect hypoglycemia and diabetes stages according to the World Health Organization standards.

Description

Keywords

SMS, Optical fiber sensors, Glucose, Glucose oxidase, LBL

Department

Ingeniería Eléctrica, Electrónica y de Comunicación / Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio Ingeniaritza / Institute of Smart Cities - ISC

Faculty/School

Degree

Doctorate program

item.page.cita

Rodríguez-Rodríguez, W. E., Rodríguez-Rodríguez, A. J., Juárez-Saldivar, A., Zamarreño, C. R., Matias, I. R. (2025) Low-cost optical fiber multimode interference biosensor based on a glucose sensitive Glucose-Oxidase enzyme thin-film. Sensors and Actuators Reports, 9, 1-10. https://doi.org/10.1016/j.snr.2024.100267.

item.page.rights

© 2024 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license

Licencia

Los documentos de Academica-e están protegidos por derechos de autor con todos los derechos reservados, a no ser que se indique lo contrario.