Reliability of measurement of the carpal tunnel and median nerve in asymptomatic subjects with ultrasound

dc.contributor.authorBueno-Gracia, Elena
dc.contributor.authorMalo-Urriés, Miguel
dc.contributor.authorRuiz de Escudero Zapico, Alazne
dc.contributor.authorRodríguez-Marco, Sonia
dc.contributor.authorJiménez-del-Barrio, Sandra
dc.contributor.authorShacklock, Michael
dc.contributor.authorEstébanez-de-Miguel, Elena
dc.contributor.authorTricás-Moreno, José Miguel
dc.contributor.departmentCiencias de la Saludes_ES
dc.contributor.departmentOsasun Zientziakeu
dc.date.accessioned2025-01-31T10:50:24Z
dc.date.available2025-01-31T10:50:24Z
dc.date.issued2017
dc.date.updated2025-01-31T10:42:40Z
dc.descriptionAcceso cerrado a este documento. No se encuentra disponible para la consulta pública. Depositado en Academica-e para cumplir con los requisitos de evaluación y acreditación académica del autor/a (sexenios, acreditaciones, etc.).
dc.description.abstractBackground Morphology of the carpal tunnel changes with varying wrist postures and compressive forces applied to the wrist. These changes may affect the morphology and pressure on the median nerve and could be used as part of the treatment of the carpal tunnel syndrome patients. Reliability of the ultrasonographic measurements of the median nerve has been widely studied. However, there is a lack of investigation regarding reliability of ultrasonographic measurements of the carpal tunnel. Objective The purpose of this study was to assess intra-tester and inter-tester reliability of measurement of dimensions of the carpal tunnel and median nerve with ultrasound in asymptomatic volunteers. Design A cross-sectional methodological study. Methods Aspects measured were mediolateral and anteroposterior diameters, flattening ratio, circularity, perimeter and cross-section area of the carpal tunnel and median nerve. Results Intra-tester reliability was excellent for the carpal tunnel (ICCs from 0.91 to 0.97) and for the median nerve (ICCs from 0.79 to 0.94) measurements. The flattening ratio of the median nerve showed good agreement (ICC = 0.68). Inter-tester reliability was excellent for the carpal tunnel measurements (ICCs from 0.76 to 0.95) and, for the cross sectional area, the perimeter and mediolateral diameter of the median nerve, the ICC values were 0.89, 0.84 and 0.81, respectively. Conclusion In the context of this study, ultrasound was a reliable instrument for measuring carpal tunnel and median nerve dimensions in asymptomatic subjects.en
dc.format.mimetypeapplication/pdfen
dc.identifier.citationBueno-Gracia, E., Malo-Urriés, M., Ruiz-de-Escudero-Zapico, A., Rodríguez-Marco, S., Jiménez-del-Barrio, S., Shacklock, M., Estébanez-de-Miguel, E., Tricás-Moreno, J. M. (2017). Reliability of measurement of the carpal tunnel and median nerve in asymptomatic subjects with ultrasound. Musculoskeletal Science and Practice, 32, 17-22. https://doi.org/10.1016/j.msksp.2017.08.001.
dc.identifier.doi10.1016/j.msksp.2017.08.001
dc.identifier.issn2468-8630
dc.identifier.urihttps://academica-e.unavarra.es/handle/2454/53234
dc.language.isoeng
dc.publisherElsevier
dc.relation.ispartofMusculoskeletal Science and Practice (2017), vol. 32
dc.relation.publisherversionhttps://doi.org/10.1016/j.msksp.2017.08.001
dc.rights.accessRightsinfo:eu-repo/semantics/closedAccess
dc.titleReliability of measurement of the carpal tunnel and median nerve in asymptomatic subjects with ultrasounden
dc.typeinfo:eu-repo/semantics/article
dspace.entity.typePublication
relation.isAuthorOfPublication8fcb0fd8-423d-401d-9b1b-1235c35c8239
relation.isAuthorOfPublication.latestForDiscovery8fcb0fd8-423d-401d-9b1b-1235c35c8239

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Acceso cerrado.pdf
Size:
136.04 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: