Zubiate Orzanco, Pablo
Loading...
Email Address
person.page.identifierURI
Birth Date
Job Title
Last Name
Zubiate Orzanco
First Name
Pablo
person.page.departamento
Ingeniería Eléctrica, Electrónica y de Comunicación
person.page.instituteName
ORCID
person.page.observainves
person.page.upna
Name
- Publications
- item.page.relationships.isAdvisorOfPublication
- item.page.relationships.isAdvisorTFEOfPublication
- item.page.relationships.isAuthorMDOfPublication
35 results
Search Results
Now showing 1 - 10 of 35
Publication Open Access Route towards a label-free optical waveguide sensing platform based on lossy mode resonances(IFSA Publishing, 2019) Ruiz Zamarreño, Carlos; Zubiate Orzanco, Pablo; Ozcariz Celaya, Aritz; Elosúa Aguado, César; Socorro Leránoz, Abián Bentor; Urrutia Azcona, Aitor; López Torres, Diego; Acha Morrás, Nerea de; Ascorbe Muruzabal, Joaquín; Vitoria Pascual, Ignacio; Imas González, José Javier; Corres Sanz, Jesús María; Díaz Lucas, Silvia; Hernáez Sáenz de Zaitigui, Miguel; Goicoechea Fernández, Javier; Arregui San Martín, Francisco Javier; Matías Maestro, Ignacio; Del Villar, Ignacio; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Gobierno de Navarra / Nafarroako Gobernua,0011-1365-2017- 000117; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa, PJUPNA26According to recent market studies of the North American company Allied Market Research, the field of photonic sensors is an emerging strategic field for the following years and it is expected to garner $18 billion by 2021. The integration of micro and nanofabrication technologies in the field of sensors has allowed the development of new technological concepts such as lab-on-a-chip which have achieved extraordinary advances in terms of detection and applicability, for example in the field of biosensors. This continuous development has allowed that equipment consisting of many complex devices that occupied a whole room a few years ago, at present it is possible to handle them in the palm of the hand; that formerly long duration processes are carried out in a matter of milliseconds and that a technology previously dedicated solely to military or scientific uses is available to the vast majority of consumers. The adequate combination of micro and nanostructured coatings with optical fiber sensors has permitted us to develop novel sensing technologies, such as the first experimental demonstration of lossy mode resonances (LMRs) for sensing applications, with more than one hundred citations and related publications in high rank journals and top conferences. In fact, fiber optic LMR-based devices have been proven as devices with one of the highest sensitivity for refractometric applications. Refractive index sensitivity is an indirect and simple indicator of how sensitive the device is to chemical and biological species, topic where this proposal is focused. Consequently, the utilization of these devices for chemical and biosensing applications is a clear opportunity that could open novel and interesting research lines and applications as well as simplify current analytical methodologies. As a result, on the basis of our previous experience with LMR based sensors to attain very high sensitivities, the objective of this paper is presenting the route for the development of label-free optical waveguide sensing platform based on LMRs that enable to explore the limits of this technology for bio-chemosensing applications.Publication Open Access Experimental demonstration of lossy mode resonance generation for transverse-magnetic and transverse-electric polarizations(Optica Publishing Group, 2013) Ruiz Zamarreño, Carlos; Zubiate Orzanco, Pablo; Sagüés García, Mikel; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta ElektronikoaThis Letter, presents the fabrication of lossy mode resonance (LMR) devices based on titanium dioxide (TiO2)/ poly(sodium 4-styrenesulfonate) (PSS) coatings deposited on side-polished D-shaped optical fibers. TiO2 thin films have been obtained by means of the layer-by-layer (LbL) self-assembly technique. LbL enables us to produce smooth and homogeneous coatings on the polished side of the fiber. This permits us to couple light from the waveguide to the TiO2-coating/external medium region at specific wavelength ranges. The generation of LMRs depends on the coating thickness, so that thicker coatings can produce more resonances. LMRs are sensitive to the external medium refractive index, which allows its utilization as refractometers. The characteristic D-shaped architecture of the devices employed in this Letter enables us to distinguish TE and TM polarizations, which had not been possible before with regular optical fibers due to their cylindrical symmetry. The results presented here show for the first time the experimental demonstration of the generation of LMRs produced by both TM and TE polarizations. More specifically, for these TiO2/PSS thin films, the TM and TM modes of the LMRs show a wavelength shift of 226 nm for the first-order LMR and 56 nm for the second-order LMR.Publication Open Access D-shape optical fiber pH sensor based on lossy mode resonances (LMRs)(IEEE, 2016-01-07) Zubiate Orzanco, Pablo; Ruiz Zamarreño, Carlos; Del Villar, Ignacio; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio IngeniaritzaThe fabrication and characterization of an optical fiber pH sensor based on Lossy Mode Resonances (LMRs) is presented. PAH/PAA polymeric thin-films fabricated onto side-polished D-shaped optical fibers are used as LMR supporting coatings. The thickness of PAH/PAA coatings can be modified as a function of the external medium pH. As a consequence of this variation, the effective refractive index of the structure will change, producing a shift of the LMR. The fabricated sensor has been used to measure pH from 4.0 to 5.0. This pH sensor showed a sensitivity of 101.3 nm per pH unit, which means a resolution of ~6×10-4 pH units by using a conventional communications Optical Spectrum Analyzer (OSA), which is an improvement over commercial pH sensors.Publication Open Access A comprehensive review of optical fiber refractometers: toward a standard comparative criterion(Wiley, 2019) Urrutia Azcona, Aitor; Del Villar, Ignacio; Zubiate Orzanco, Pablo; Ruiz Zamarreño, Carlos; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio Ingeniaritza; Institute of Smart Cities - ISCThanks to the peculiarities of optical fiber and its ability to be combined with nanotechnology, precise and accurate measurements of the changes in optical properties (i.e., refractive index) of the medium surrounding the fiber are becoming possible with a high degree of performance. Thus, optical fiber sensors (OFSs) are increasingly finding applications in biochemistry and biomedicine. Here, all types of optical fiber refractometers are covered, and they are classified into three main groups: interferometers, grating-based structures, and resonance-based structures (the resonance is induced by coating the optical fiber sensor with a thin film). The performance of these different structures is compared by means of the most common parameters: sensitivity, full width at half minimum or maximum, figure of merit, and quality factor. The aim here is to provide a reliable and easy-to-use tool to compare the performance of the most recent developments on fiber optic refractometers.Publication Open Access Giant sensitivity of optical fiber sensors by means of lossy moderesonance(Elsevier, 2016) Arregui San Martín, Francisco Javier; Del Villar, Ignacio; Ruiz Zamarreño, Carlos; Zubiate Orzanco, Pablo; Matías Maestro, Ignacio; Ingeniaritza Elektrikoa eta Elektronikoa; Institute of Smart Cities - ISC; Ingeniería Eléctrica y ElectrónicaHere we show an optical refractometer with a giant sensitivity of 304,360 nm per refractive index unit(nm/RIU). This sensitivity corresponds to a resolution of 3.28 × 10−9RIU if a standard optical spectrumanalyzer with a resolution of 1 pm is used. This record sensitivity is obtained by means of a lossy moderesonance (LMR) optical fiber sensor in a surrounding media with refractive index around 1.45. Thisachievement implies that the utilization of the LMR phenomenon opens the door to devices and systemsthat can beat, in terms of sensitivity, those used currently in real-time biomolecular analysis such assurface plasmon resonance (SPR) devices.Publication Open Access Lossy mode resonances biosensor for the detection of C-reactive protein(Optica Publishing Group, 2016) Zubiate Orzanco, Pablo; Ruiz Zamarreño, Carlos; Sánchez Zábal, Pedro; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute of Smart Cities - ISC; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Universidad Pública de Navarra / Nafarroako Unibertsitate PublikoaThe fabrication and characterization of optical fiber biosensor based on Lossy Mode Resonances (LMR) to detect C-reactive protein (CRP) are presented. Indium tin oxide (ITO) coatings deposited on side-polished D-shaped optical fibers are used as LMR supporting coatings. The aptamer was immobilized on the ITO film using the Layer-by-Layer (LbL) nano-assembly process. The optical fiber sensor presented shows a high selectivity and low limit detection.Publication Open Access Optical sensors based on lossy-mode resonances(Elsevier Science, 2017) Matías Maestro, Ignacio; Ascorbe Muruzabal, Joaquín; Acha Morrás, Nerea de; López Torres, Diego; Zubiate Orzanco, Pablo; Sánchez Zábal, Pedro; Urrutia Azcona, Aitor; Socorro Leránoz, Abián Bentor; Rivero Fuente, Pedro J.; Hernáez Sáenz de Zaitigui, Miguel; Elosúa Aguado, César; Goicoechea Fernández, Javier; Bariáin Aisa, Cándido; Corres Sanz, Jesús María; Ruiz Zamarreño, Carlos; Arregui San Martín, Francisco Javier; Del Villar, Ignacio; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Institute of Smart Cities - ISCPublication Open Access Ammonia gas optical sensor based on lossy mode resonances(IEEE, 2023) Armas, Dayron; Zubiate Orzanco, Pablo; Ruiz Zamarreño, Carlos; Matías Maestro, Ignacio; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute of Smart Cities - ISC; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio IngeniaritzarenThis letter presents the fabrication and characterization of an ammonia (NH 3) gas optical sensor based on lossy mode resonances (LMRs). A chromium (III) oxide (Cr 2 O 3) thin film deposited onto a planar waveguide was used as LMR supporting coating. The obtained LMR shows a maximum attenuation wavelength or resonance wavelength centered at 673 nm. The optical properties of the coating can be modified as a function of the presence and concentration of NH 3 in the external medium. Consequently, the refractive index of the Cr 2 O 3 thin film will change, producing a red-shift of the resonance wavelength. Obtained devices were tested for different concentrations of NH 3 as well as repetitive cycles. Concentrations as low as 10 ppbv of NH 3 were detected at room temperature. Machine learning regression models were used to mitigate the cross-sensitivity of the device under temperature and humidity fluctuations.Publication Open Access Fiber-based label-free D-dimer detection for early diagnosis of venous thromboembolism(SPIE, 2020) Zubiate Orzanco, Pablo; Urrutia Azcona, Aitor; Ruiz Zamarreño, Carlos; Fernández Irigoyen, Joaquín; Giannetti, Ambra; Baldini, Francesco; Díaz Lucas, Silvia; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Santamaría Martínez, Enrique; Del Villar, Ignacio; Chiavaioli, Francesco; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de ComunicaciónD-dimer is a useful diagnostic biomarker for deep vein thrombosis or pulmonary embolism, collectively referred to as venous thromboembolism (VTE). The ability to detect in real-time the amount of D-dimer with a fast and reliable method is a key step to anticipate the appearance of these diseases. The combination of fiber-optic-based platforms for biosensing with the nanotechnologies is opening up the chance for the development of in situ, portable, lightweight, versatile, reliable and high-performance optical sensing devices towards lab-on-fiber technology. The generation of lossy mode resonances (LMRs) by means of the deposition of nm-thick absorbing metal-oxide films on special geometric-modified fibers allows measuring precisely and accurately surface refractive index changes, which are due to the binding interaction between a biological recognition element and the analyte under investigation. This approach enhances the light-matter interaction in a strong way, thus turning out to be more sensitive compared to other optical technology platforms, such as fiber gratings or surface plasmon resonance. Here, the results of a highly specific and sensitive biosensor for the detection of D-dimer based on LMR in fiber-optics are presented by monitoring in real-time the shift of the LMR related to the biomolecule interactions thanks to a conventional wavelength-interrogation system and an ad-hoc developed microfluidics. A detection limit of 100 ng/mL, a value 5-fold below the clinical cutoff value, has been attained for D-dimer spiked in human serum. The comparison of the results achieved with proteomics-based methodologies, which allows for the identification of betaand gamma-chains of fibrinogen, demonstrates the ability of our platform to specifically (>90%) recognize D-dimer.Publication Open Access High sensitive and selective C-reactive protein detection by means of lossy mode resonance based optical fiber devices(Elsevier, 2017) Zubiate Orzanco, Pablo; Ruiz Zamarreño, Carlos; Sánchez Zábal, Pedro; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Institute of Smart Cities - ISC; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Universidad Pública de Navarra / Nafarroako Unibertsitate PublikoaThis work presents the development of high sensitive, selective, fast and reusable C-reactive protein (CRP) aptasensors. This novel approach takes advantage of the utilization of high sensitive refractometers based on Lossy Mode Resonances generated by thin indium tin oxide (ITO) films fabricated onto the planar region of D-shaped optical fibers. CRP selectivity is obtained by means of the adhesion of a CRP specific aptamer chain onto the ITO film using the Layer-by-Layer (LbL) nano-assembly fabrication process. The sensing mechanism relies on resonance wavelength shifts originated by refractive index variations of the aptamer chain in presence of the target molecule. Fabricated devices show high selectivity to CRP when compared with other target molecules, such as urea or creatinine, while maintaining a low detection limit (0.0625 mg/L) and fast response time (61 s). Additionally, these sensors show a repetitive response for several days and are reusable after a cleaning process in ultrapure water.