Del Villar, Ignacio

Loading...
Profile Picture

Email Address

Birth Date

Job Title

Last Name

Del Villar

First Name

Ignacio

person.page.departamento

Ingeniería Eléctrica, Electrónica y de Comunicación

person.page.instituteName

ISC. Institute of Smart Cities

person.page.observainves

person.page.upna

Name

Search Results

Now showing 1 - 10 of 19
  • PublicationOpen Access
    Giant sensitivity of optical fiber sensors by means of lossy moderesonance
    (Elsevier, 2016) Arregui San Martín, Francisco Javier; Del Villar, Ignacio; Ruiz Zamarreño, Carlos; Zubiate Orzanco, Pablo; Matías Maestro, Ignacio; Ingeniaritza Elektrikoa eta Elektronikoa; Institute of Smart Cities - ISC; Ingeniería Eléctrica y Electrónica
    Here we show an optical refractometer with a giant sensitivity of 304,360 nm per refractive index unit(nm/RIU). This sensitivity corresponds to a resolution of 3.28 × 10−9RIU if a standard optical spectrumanalyzer with a resolution of 1 pm is used. This record sensitivity is obtained by means of a lossy moderesonance (LMR) optical fiber sensor in a surrounding media with refractive index around 1.45. Thisachievement implies that the utilization of the LMR phenomenon opens the door to devices and systemsthat can beat, in terms of sensitivity, those used currently in real-time biomolecular analysis such assurface plasmon resonance (SPR) devices.
  • PublicationOpen Access
    Femtomolar detection by nanocoated fiber label-free biosensors
    (American Chemical Society, 2018) Chiavaioli, Francesco; Zubiate Orzanco, Pablo; Del Villar, Ignacio; Ruiz Zamarreño, Carlos; Giannetti, Ambra; Tombelli, Sara; Trono, Cosimo; Arregui San Martín, Francisco Javier; Matías Maestro, Ignacio; Baldini, Francesco; Institute of Smart Cities - ISC; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Gobierno de Navarra / Nafarroako Gobernua
    The advent of optical fibre-based biosensors combined with that of nanotechnologies has provided an oppor-tunity for developing in situ, portable, lightweight, versatile and high-performance optical sensing platforms. We report on the generation of lossy mode resonances by the deposition of nm-thick metal oxide films on optical fibres, which makes it possible to measure precisely and accurately the changes in optical properties of the fibre-surrounding medium with very high sensitivity compared to other technology platforms, such as long period gratings or surface plasmon resonances, the gold standard in label-free and real-time biomolecular interaction analysis. This property, combined with the application of specialty structures such as D-shaped fibres, permits enhancing the light-matter interaction. SEM and TEM imaging together with X-EDS tool have been utilised to characterise the two films used, i.e. indium tin oxide and tin dioxide. More-over, the experimental transmission spectra obtained after the deposition of the nanocoatings have been numerically cor-roborated by means of wave propagation methods. With the use of a conventional wavelength interrogation system and ad-hoc developed microfluidics, the shift of the lossy mode resonance can be reliably recorded in response to very low analyte concentrations. Repeated experiments confirm a big leap in performance thanks to the capability to detect femtomolar concentrations in human serum, improving the detection limit by three orders of magnitude when compared with other fibre-based configurations. The biosensor has been regenerated several times by injecting sodium dodecyl sul-phate, which proves the capability of sensor to be reused.
  • PublicationOpen Access
    Surface exciton polariton resonances (SEPR)-based sensors
    (Elsevier, 2023) Vitoria Pascual, Ignacio; Ruiz Zamarreño, Carlos; Ozcariz Celaya, Aritz; Imas González, José Javier; Del Villar, Ignacio; Matías Maestro, Ignacio; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación
    A new type of resonance in the development of sensors using long-range surface exciton polariton (LRSEP) phenomena has been coined: surface exciton plasmon resonance (SEPR). The resonance was obtained in the reflected spectrum of a Kretschmann-Raether setup with a two-coupled-interface structure composed of 412 nm magnesium fluoride and 50 nm chromium thin films. The roles of different parameters such as thicknesses of the films and the incidence angles have been simulated. Some preliminary experimental results show a promising performance with a shift of the resonance central wavelength with changes in the incidence angle of -136.52 nm/° and a sensitivity of 23,221 nm/refractive index unit.
  • PublicationOpen Access
    Sensors based on thin-film coated cladding removed multimode optical fiber and single-mode multimode single-mode fiber: a comparative study
    (Hindawi Publishing Corporation, 2015) Del Villar, Ignacio; Socorro Leránoz, Abián Bentor; Hernáez Sáenz de Zaitigui, Miguel; Corres Sanz, Jesús María; Ruiz Zamarreño, Carlos; Sánchez Zábal, Pedro; Arregui San Martín, Francisco Javier; Matías Maestro, Ignacio; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa
    Two simple optical fibre structures that do not require the inscription of a grating, a cladding removed multimode optical fibre (CRMOF) and a single-mode multimode single-mode structure (SMS), are compared in terms of their adequateness for sensing once they are coated with thin-films.The thin-film deposited (TiO2/PSS) permits increasing the sensitivity to surrounding medium refractive index. The results obtained can be extrapolated to other fields such as biological or chemical sensing just by replacing the thin-film by a specific material.
  • PublicationOpen Access
    High sensitivity lossy-mode resonance refractometer using low refractive index PFA planar waveguide
    (Elsevier, 2023) Domínguez Rodríguez, Ismel; Corres Sanz, Jesús María; Matías Maestro, Ignacio; Ascorbe Muruzabal, Joaquín; Del Villar, Ignacio; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute of Smart Cities - ISC; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    In this work a new strategy to improve the sensitivity of refractometers based on lossy-mode resonances has been proved. The proximity of the PFA (tetrafluoroethylene-perfluoro polymer) substrate refractive index to that of water has permitted to implement an optical refractometer with a sensitivity of 41,034 nm per refractive index unit (nm/RIU) for refractive indices ranging from 1.3318 to 1.3347. The work is supported with both theoretical and experimental results. This high sensitivity can be used for the development of LMR based chemical sensors and biosensors, where a low limit of detection is required, with the additional advantage of a simple disposable planar configuration.
  • PublicationOpen Access
    Generation of lossy mode resonances in planar waveguides toward development of humidity sensors
    (IEEE, 2019) Fuentes Lorenzo, Omar; Corres Sanz, Jesús María; Matías Maestro, Ignacio; Del Villar, Ignacio; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación
    Lossy mode resonances (LMRs) are typically obtained with optical fibre. The Kretschmann configuration is an alternative but LMRs are generated with angles approaching grazing incidence. In this work, a new setup is explored, based on the lateral incidence of light on conventional planar waveguides such as glass slides or coverslips. Indium tin oxide was deposited onto both types of waveguides generating LMRs. The results of the simulations carried out agree well with the experimental results. As an example of the potential of this new and simple optical configuration, a humidity sensor with a sensitivity of 0.212 nm/% relative humidity (RH) in the range from 65% to 90% of RH was developed, which expedites the development of other types of sensors already explored with LMR-based optical fibre sensors.
  • PublicationOpen Access
    Lossy mode resonance enabling ultra-low detection limit for fibre-optic biosensors (INVITED)
    (Springer, 2020) Chiavaioli, Francesco; Giannetti, Ambra; Tombelli, Sara; Trono, Cosimo; Del Villar, Ignacio; Matías Maestro, Ignacio; Zubiate Orzanco, Pablo; Ruiz Zamarreño, Carlos; Arregui San Martín, Francisco Javier; Baldini, Francesco; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Gobierno de Navarra / Nafarroako Gobernua, 72/2015
    The combination of optical fibre-based biosensors with nanotechnologies is providing the opportunity for the development of in situ, portable, lightweight, versatile and high-sensitivity optical sensing platforms. We report on the generation of lossy mode resonances (LMRs) by means of the deposition of nm-thick SnO2 film on optical fibres. This allows measuring precisely and accurately the changes in refractive index of the fibre-surrounding medium with very high sensitivity compared to other optical technology platforms, such as long period grating or surface plasmon resonance. This approach, mixed with the use of specialty fiber structures such as Dshaped fibres, allows improving the light-matter interaction in strong way. Different imaging systems, i.e. SEM and TEM along with X-EDS tool, have been used to study the optical features of the fiber coating. The shift of the LMR has been monitored in real-time thanks to conventional wavelength interrogation system and ad hoc developed microfluidics. A big leap in performance has been attained by detecting femtomolar concentrations in human serum. The biosensor reusability has been also tested by using a solution of sodium dodecyl sulphate.
  • PublicationOpen Access
    Lossy mode resonance based microfluidic platform developed on planar waveguide for biosensing applications
    (MDPI, 2022) Benítez Pérez, Melanys; Zubiate Orzanco, Pablo; Del Villar, Ignacio; Socorro Leránoz, Abián Bentor; Matías Maestro, Ignacio; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    The development of resonance phenomena-based optical biosensors has gained relevance in recent years due to the excellent optical fiber properties and progress in the research on materials and techniques that allow resonance generation. However, for lossy mode resonance (LMR)-based sensors, the optical fiber presents disadvantages, such as the need for splicing the sensor head and the complex polarization control. To avoid these issues, planar waveguides such as coverslips are easier to handle, cost-effective, and more robust structures. In this work, a microfluidic LMR-based planar waveguide platform was proposed, and its use for biosensing applications was evaluated by detecting anti-immunoglobulin G (anti-IgG). In order to generate the wavelength resonance, the sensor surface was coated with a titanium dioxide (TiO2) thin-film. IgG antibodies were immobilized by covalent binding, and the detection assay was carried out by injecting anti-IgG in PBS buffer solutions from 5 to 20 μg/mL. The LMR wavelength shifted to higher values when increasing the analyte concentration, which means that the proposed system was able to detect the IgG/anti-IgG binding. The calibration curve was built from the experimental data obtained in three repetitions of the assay. In this way, a prototype of an LMR-based biosensing microfluidic platform developed on planar substrates was obtained for the first time
  • PublicationOpen Access
    Multichannel refractometer based on lossy mode resonances
    (IEEE, 2022) Fuentes Lorenzo, Omar; Corres Sanz, Jesús María; Domínguez Rodríguez, Ismel; Del Villar, Ignacio; Matías Maestro, Ignacio; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    In this work a new multiparameter sensor platform based on lossy mode resonances is presented. The structure consists of a soda-lime optical slab waveguide butt-coupled to multimode optical fibers. A variable thickness thin-film is deposited to generate multiple independent resonances on the same waveguide, which can be monitored using a single spectrometer. In order to show the potentiality of the structure, a broad resonance was selectively narrowed by etching sections of the LMR producer thin film. The spectral width is progressively reduced, allowing to selectively isolate independent resonances, which opens the path for multiple LMR generation in the same spectra in a multiparameter sensing platform. The experimental results were corroborated with a theoretical analysis based on the finite difference method (FDM). As a proof of concept, two refractometers on the same waveguide were fabricated and tested using PDMS cells. This platform can be easily miniaturized in order to integrate multiple sensors at low cost, what can be of interest for the development of multi-analyte biosensors probes. IEEE
  • PublicationOpen Access
    Fiber-optic lossy mode resonance sensors
    (Elsevier, 2014) Arregui San Martín, Francisco Javier; Del Villar, Ignacio; Corres Sanz, Jesús María; Goicoechea Fernández, Javier; Ruiz Zamarreño, Carlos; Elosúa Aguado, César; Hernáez Sáenz de Zaitigui, Miguel; Rivero Fuente, Pedro J.; Socorro Leránoz, Abián Bentor; Urrutia Azcona, Aitor; Sánchez Zábal, Pedro; Zubiate Orzanco, Pablo; López Torres, Diego; Acha Morrás, Nerea de; Matías Maestro, Ignacio; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Gobierno de Navarra / Nafarroako Gobernua
    In the last 4 years, experimental evidences about the potential use of optical sensors based on Lossy Mode Resonances (LMR) have been presented in the literature. These LMR sensors have some similarities with Surface Plasmon Resonance (SPR) sensors, the gold standard in label-free, real-time biomolecular interaction analysis. In these new LMR sensors, if the non-metallic nanocladding of an optical waveguide fulfills the conditions explained in this work, coupling of light to the cladding modes happens at certain resonance wavelengths, which enables the use of LMR devices as refractometers and opens the door to diverse applications such as in biology and proteomics research. These highly sensitive refractometers have already shown sensitivities higher than 20,000 nm/RIU or 5x10-7 RIU and, given the youth of this field, it is expected to achieve even better values.