Person:
Pascual Miqueleiz, Julio María

Loading...
Profile Picture

Email Address

Birth Date

Research Projects

Organizational Units

Job Title

Last Name

Pascual Miqueleiz

First Name

Julio María

person.page.departamento

Ingeniería Eléctrica y Electrónica

ORCID

0000-0002-9495-5910

person.page.upna

810225

Name

Search Results

Now showing 1 - 10 of 11
  • PublicationOpen Access
    Fuzzy logic-based energy management system design for residential grid-connected microgrids
    (IEEE, 2018) Arcos Avilés, Diego; Pascual Miqueleiz, Julio María; Marroyo Palomo, Luis; Sanchis Gúrpide, Pablo; Guinjoan Gispert, Francesc; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Gobierno de Navarra / Nafarroako Gobernua
    This paper presents the design of a low complexity fuzzy logic controller of only 25-rules to be embedded in an energy management system for a residential grid-connected microgrid including renewable energy sources and storage capability. The system assumes that neither the renewable generation nor the load demand is controllable. The main goal of the design is to minimize the grid power profile fluctuations while keeping the battery state of charge within secure limits. Instead of using forecasting-based methods, the proposed approach use both the microgrid energy rate-of-change and the battery state of charge to increase, decrease, or maintain the power delivered/absorbed by the mains. The controller design parameters (membership functions and rule-base) are adjusted to optimize a pre-defined set of quality criteria of the microgrid behavior. A comparison with other proposals seeking the same goal is presented at simulation level, whereas the features of the proposed design are experimentally tested on a real residential microgrid implemented at the Public University of Navarre.
  • PublicationOpen Access
    Energy management for an electro-thermal renewable based residential microgrid with energy balance forecasting and demand side management
    (Elsevier, 2021) Pascual Miqueleiz, Julio María; Arcos Avilés, Diego; Ursúa Rubio, Alfredo; Sanchis Gúrpide, Pablo; Marroyo Palomo, Luis; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute of Smart Cities - ISC; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    This paper proposes an energy management strategy for a residential microgrid comprising photovoltaic (PV) panels, a small wind turbine and solar thermal collectors. The microgrid can control the power exchanged with the grid thanks to a battery and a controllable electric water heater, which provide two degrees of freedom to the control strategy. As input data, the proposed control strategy uses the battery state of charge (SOC), the temperature of the hot water tank, the power of each microgrid element as well as the demand and renewable generation forecasts. By using forecasted data and by controlling the electric water heater, the strategy is able to achieve a better grid power profile while using a smaller battery than previous works, hence reducing the overall cost of the system. The strategy is tested by means of simulation with real data for one year and it is also experimentally validated in the microgrid built at the Renewable Energy Laboratory at the UPNA.
  • PublicationOpen Access
    Fuzzy-based energy management of a residential electro-thermal microgrid based on power forecasting
    (IEEE, 2018) Arcos Avilés, Diego; Gordillo, Rodolfo; Guinjoan Gispert, Francesc; Sanchis Gúrpide, Pablo; Pascual Miqueleiz, Julio María; Marietta, Martin P.; Marroyo Palomo, Luis; Ibarra, Alexander; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    In this paper, an energy management strategy based on microgrid power forecasting is applied to a residential grid-connected electro-thermal microgrid with the aim of smoothing the power profile exchanged with the grid. The microgrid architecture under study considers electrical and thermal renewable generation, energy storage system (ESS), and loads. The proposed strategy manages the energy stored in the ESS to cover part of the energy required by the thermal generation system for supplying domestic hot water to the residence. The simulation results using real data and the comparison with previous strategy have demonstrated the effectiveness of the proposed strategy.
  • PublicationOpen Access
    Long-term degradation rate of crystalline silicon PV modules at commercial PV plants: an 82-MWp assessment over 10 years
    (Wiley, 2021) Pascual Miqueleiz, Julio María; Martínez Moreno, Francisco; García Solano, Miguel; Marcos Álvarez, Javier; Marroyo Palomo, Luis; Lorenzo Pigueiras, Eduardo; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación
    Due to high competitiveness in the PV sector, despite the low degradation rate of crystalline silicon PV modules (below 0.5%/year), it is still important for utilities to know its actual value due to its impact on energy yield and hence, profitability, over the lifetime of a PV plant. However, uncertainties related to both the influence of downtime periods due to problems that may appear under normal operation of a commercial PV plant and to the measurement of degradation rates at PV plant level make this a challenging task. In order to obtain a significant value, in this paper, three measuring methods with different uncertainty sources are used for 82 MWp of PV modules on different locations in Spain and Portugal over 10 years. According to the different methods used and PV plants analyzed, excluding PV plants with problems, a range of degradation rates between 0.01 and 0.47%/year has been found. The overall average value observed is 0.27%/year. The findings of this work have also revealed the great importance of good operation and maintenance practices in order to keep overall low degradation rates.
  • PublicationOpen Access
    An energy management system design using fuzzy logic control: smoothing the grid power profile of a residential electro-thermal microgrid
    (IEEE, 2021) Arcos Avilés, Diego; Pascual Miqueleiz, Julio María; Guinjoan Gispert, Francesc; Marroyo Palomo, Luis; García Gutiérrez, Gabriel; Gordillo, Rodolfo; Llanos, Jacqueline; Sanchis Gúrpide, Pablo; Motoasca, Emilia; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    This work deals with the design of a Fuzzy Logic Control (FLC) based Energy Management System (EMS) for smoothing the grid power prole of a grid-connected electro-thermal microgrid. The case study aims to design an Energy Management System (EMS) to reduce the impact on the grid power when renewable energy sources are incorporated to pre-existing grid-connected household appliances. The scenario considers a residential microgrid comprising photovoltaic and wind generators, at-plate collectors, electric and thermal loads and electrical and thermal energy storage systems and assumes that neither renewable generation nor the electrical and thermal load demands are controllable. The EMS is built through two low-complexity FLC blocks of only 25 rules each. The first one is in charge of smoothing the power prfile exchanged with the grid, whereas the second FLC block drives the power of the Electrical Water Heater (EWH). The EMS uses the forecast of the electrical and thermal power balance between generation and consumption to predict the microgrid behavior, for each 15-minute interval, over the next 12 hours. Simulations results, using real one-year measured data show that the proposed EMS design achieves 11.4% reduction of the maximum power absorbed from the grid and an outstanding reduction of the grid power profile ramp-rates when compared with other state-of-the-art studies.
  • PublicationOpen Access
    Implementation and control of a residential electrothermal microgrid based on renewable energies, a hybrid storage system and demand side management
    (MDPI, 2014) Pascual Miqueleiz, Julio María; Sanchis Gúrpide, Pablo; Marroyo Palomo, Luis; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Gobierno de Navarra / Nafarroako Gobernua
    This paper proposes an energy management strategy for a residential electrothermal microgrid, based on renewable energy sources. While grid connected, it makes use of a hybrid electrothermal storage system, formed by a battery and a hot water tank along with an electrical water heater as a controllable load, which make possible the energy management within the microgrid. The microgrid emulates the operation of a single family home with domestic hot water (DHW) consumption, a heating, ventilation and air conditioning (HVAC) system as well as the typical electric loads. An energy management strategy has been designed which optimizes the power exchanged with the grid profile in terms of peaks and fluctuations, in applications with high penetration levels of renewables. The proposed energy management strategy has been evaluated and validated experimentally in a full scale residential microgrid built in our Renewable Energy Laboratory, by means of continuous operation under real conditions. The results show that the combination of electric and thermal storage systems with controllable loads is a promising technology that could maximize the penetration level of renewable energies in the electric system.
  • PublicationOpen Access
    Analysis of polyamide and fluoropolymer backsheets: Degradation and insulation failure in field-aged photovoltaic modules
    (John Wiley & Sons, 2022) Pascual Miqueleiz, Julio María; García Solano, Miguel; Marcos Álvarez, Javier; Marroyo Palomo, Luis; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute of Smart Cities - ISC; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    Durability of photovoltaic (PV) modules is of great concern not only from the point of view of cost-effectiveness but also from the point of view of safety and sustainability. The backsheet of a PV module is one of the most critical parts of the PV module from the point of view of protection and also one of the most important sources of PV modules' failure; hence, it is of great importance to understand its different forms of failure. In this paper we analyze the case of an 8-MW PV plant, which had suffered a rapid degradation of their PV modules' backsheets. The case is especially relevant as all the PV modules are from the same model and manufacturer but with different backsheet materials (polyamide and fluoropolymer) and different times of exposure: on one hand, all PV modules originally installed in the plant (i.e., 6 years under operation when tested), and also, extra modules that had been stored indoors for replacement and had been mounted in the plant for less than 1 year when tested, serving as reference modules. In this paper we present the signs of degradation of these PV modules after different times of exposure under real operation using different on-field and laboratory tests. We propose different techniques for rapid diagnosis of backsheet degradation so that the problem can be detected at a very early stage, before it results in major energy losses or in safety issues.
  • PublicationOpen Access
    On the on-site measurement of the degradation rate of crystalline silicon PV modules at plant level
    (IEEE, 2018) Pascual Miqueleiz, Julio María; Berrueta Irigoyen, Alberto; Marcos Álvarez, Javier; García Solano, Miguel; Marroyo Palomo, Luis; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación
    This paper proposes a method for measuring the degradation rate of crystalline silicon PV modules at plant level in two different ways as a form of verification. As actual levels of degradation rate have been observed to be as low as 0.2%/a, the uncertainties make it difficult to measure this value accurately at plant level. However, despite the low value, it is still important to know the actual degradation rate due to its impact on energy yield. In this paper, two ways of measuring the degradation rate at plant level are proposed. These two methods, with different uncertainty sources, are proposed to be used jointly in order to have a better approach to the real value. Finally, an example of measurement in a 1.78 MW PV plant is presented.
  • PublicationOpen Access
    Adjustment of the fuzzy logic controller parameters of the energy management strategy of a grid-tied domestic electro-thermal microgrid using the Cuckoo search algorithm
    (IEEE, 2019) Arcos Avilés, Diego; García Gutiérrez, Gabriel; Guinjoan Gispert, Francesc; Pascual Miqueleiz, Julio María; Marroyo Palomo, Luis; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    During the last century, population growth, together with economic development, has considerably increased the energy demand and, although renewable energies are becoming an alternative, still total energy supply is mainly non-renewable, causing well-known negative effects such as pollution and global warming. On the other hand, technological advances have allowed the development of increasingly efficient distributed generation systems and the emergence of microgrids, whose studies have been focused on architecture, elements, and objectives of the associated energy management strategies. In this regard, energy management strategies based on a Fuzzy Logic controller have been developed for electro-thermal microgrids where parameter optimization has been carried out through heuristic procedures of trial and error with acceptable results but involving a high computational cost. To solve the aforementioned drawbacks, in the present work the use of Cuckoo Search optimization nature-inspired algorithm that allows the adjustment of Fuzzy Logic controller parameters and ensures a higher quality of energy management is proposed. Obtained results show encouraging outcomes for the use of these meta-heuristic optimization algorithms.
  • PublicationOpen Access
    Economic analysis of residential PV self-consumption systems with Li-ion batteries under different billing scenarios
    (IEEE, 2019) Galilea Gil, Carlos; Pascual Miqueleiz, Julio María; Berrueta Irigoyen, Alberto; Ursúa Rubio, Alfredo; Marroyo Palomo, Luis; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Gobierno de Navarra / Nafarroako Gobernua, 0011-1411-2017-000021
    In this paper, an economic analysis for four houses with a PV self-consumption system with and without Li-ion batteries is carried out. In particular three different ways of sizing PV and batteries are analyzed under three different billing scenarios for the compensation of surplus energy injected into the grid. All methods run under the same energy strategy, which maximizes self-consumption. The three billing scenarios are: (1) no retribution for surplus energy, (2) retribution at pool price (net billing), and (3) monthly net metering. This study shows how fixed costs make these systems just profitable for small systems. Moreover, the results show how the battery cost and lifespan affects the final profitability of the system and what future evolution in these factors is needed for making these systems profitable under different billing methods.