Multiparameter sensor based on a multiinterferometric serial configuration for temperature and strain measurements
Date
Director
Publisher
Impacto
Abstract
In this work, a multi-parameter point sensor based on the combination of Fabry-Perot (FP) and the anti-resonant (AR) reflecting guidance in cascade configuration is proposed and experimentally demonstrated. This structure, based on FP interference and AR reflecting guidance, was fabricated with two different air micro-cavities. The attained experimental results showed different strain and temperature sensitivities for the antiresonance contribution. However, when analyzing the FP interference, only strain sensitivity was observed, demonstrating that this air micro-cavity was also insensitive to temperature variations.
Description
Keywords
Department
Faculty/School
Degree
Doctorate program
item.page.cita
item.page.rights
© 2021 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other work.
Los documentos de Academica-e están protegidos por derechos de autor con todos los derechos reservados, a no ser que se indique lo contrario.