Reproducibility of the energy metabolism response to an oral glucose tolerance test: influence of a postcalorimetric correction procedure

Date

2022

Authors

Sánchez Delgado, Guillermo
Jurado Fasoli, Lucas
Galgani, José E.
Ruiz, Jonatan R.

Director

Publisher

Springer
Acceso abierto / Sarbide irekia
Artículo / Artikulua
Versión publicada / Argitaratu den bertsioa

Project identifier

  • AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/DEP2016-79512-R/
  • MECD/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/FPU15%2F04059/ES/ recolecta
  • //FPU19%2F01609/
Impacto
No disponible en Scopus

Abstract

Purpose Metabolic fexibility (MetF), which is a surrogate of metabolic health, can be assessed by the change in the respiratory exchange ratio (RER) in response to an oral glucose tolerance test (OGTT). We aimed to determine the day-to-day reproducibility of the energy expenditure (EE) and RER response to an OGTT, and whether a simulation-based postcalorimetric correction of metabolic cart readouts improves day-to-day reproducibility. Methods The EE was assessed (12 young adults, 6 women, 27±2 years old) using an Omnical metabolic cart (Maastricht Instruments, Maastricht, The Netherlands) after an overnight fast (12 h) and after a 75-g oral glucose dose on 2 separate days (48 h). On both days, we assessed EE in 7 periods (one 30-min baseline and six 15-min postprandial). The ICcE was performed immediately after each recording period, and capillary glucose concentration (using a digital glucometer) was determined. Results We observed a high day-to-day reproducibility for the assessed RER (coefcients of variation [CV]<4%) and EE (CVs<9%) in the 7 diferent periods. In contrast, the RER and EE areas under the curve showed a low day-to-day reproducibility (CV=22% and 56%, respectively). Contrary to our expectations, the postcalorimetric correction procedure did not infuence the day-to-day reproducibility of the energy metabolism response, possibly because the Omnical’s accuracy was~100%. Conclusion Our study demonstrates that the energy metabolism response to an OGTT is poorly reproducible (CVs>20%) even using a very accurate metabolic cart. Furthermore, the postcalorimetric correction procedure did not infuence the day-to-day reproducibility. Trial registration NCT04320433; March 25, 2020.

Description

Keywords

Glucose tolerance, Indirect calorimetry, Metabolic cart, Postprandial metabolism, Reliability

Department

Institute on Innovation and Sustainable Development in Food Chain - ISFOOD

Faculty/School

Degree

Doctorate program

item.page.cita

Alcantara, J. M. A., Sanchez-Delgado, G., Jurado-Fasoli, L., Galgani, J. E., Labayen, I., & Ruiz, J. R. (2022). Reproducibility of the energy metabolism response to an oral glucose tolerance test: Influence of a postcalorimetric correction procedure. European Journal of Nutrition. https://doi.org/10.1007/s00394-022-02986-w

item.page.rights

© The Author(s) 2022.This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly

Licencia

Los documentos de Academica-e están protegidos por derechos de autor con todos los derechos reservados, a no ser que se indique lo contrario.